Metallurgical ContentMINERAL PROCESSING FORMULASPulp DensitiesCalculation of Circulating Load in a ClassifierCalculation of Classifier EfficiencyScreen EfficiencyMeasure Tonnage by Water Ratio Pulp DilutionPulp Density TablesConcentration and Recovery FormulasTwoProduct FormulasThreeProduct FormulasReagent Consumption CalculationsLiquidSolid Relationships Specific Gravity ...We are a professional mining machinery manufacturer, the main equipment including: jaw crusher, cone crusher and other sandstone equipment;Ball mill, flotation machine, concentrator and other beneficiation equipment; Powder Grinding Plant, rotary dryer, briquette machine, mining, metallurgy and other related equipment. which can crush all kinds of metal and non-metallic ore, also can be dry grinding and wet grinding.If you are interested in our products or want to visit the nearby production site, you can click the button below to consult us.Welcome to our factory to test machine for free!
Ore processing plant means that extracts and purifies some elements in the raw ore through a series of complex ore beneficiation flow and professional beneficiation equipment. The refined concentrate powder is mainly used in metallurgy and industry base.
Further DetailsApplication Area:Building materials, chemicals, fertilizer, metallurgy, mining, refractory, ceramic, steel, thermal power, coal, etc.
Further DetailsMagnetic separation makes use of magnetic differences between minerals to separate material, which occupies a very important position in iron ore separation field. Magnetic separating plant has the advantages of energy saving, high efficiency and high
Further DetailsMain Equipment:Jaw crusher, impact crusher, hammer crusher, vibrating screen, classifier, ball mill, etc.
Further DetailsStone crushing plant is also called rock crushing plant and stone production line, which is the professional industrial machine to crush sand and stones. It is mainly composed of vibrating feeder, jaw crusher, impact crusher, vibrating screen, belt con
Further DetailsThe 200t/h granite crushing plant in Russia uses HPT220 hydraulic cone crusher as the core crushing equipment
Further DetailsMetallurgical ContentMINERAL PROCESSING FORMULASPulp DensitiesCalculation of Circulating Load in a ClassifierCalculation of Classifier EfficiencyScreen EfficiencyMeasure Tonnage by Water Ratio Pulp DilutionPulp Density TablesConcentration and Recovery FormulasTwoProduct FormulasThreeProduct FormulasReagent Consumption CalculationsLiquidSolid Relationships Specific Gravity
Further DetailsSlurry Calculator Help Introduction The Paterson Cooke Slurry Toolkit is a simple calculator of slurry properties Use it to determine the concentration of the slurry if you know the density or vice versa It is also a useful tool to determine slurry flow properties The toolkit is meant for use by engineers technicians and
Further DetailsApr 04 2019 · Add a safety factor of 10 to 20 Tons per hour x 12 safety factor Chiller size in tons 2 Calculate a simplified MCΔT This method is ideal for measuring the actual load of a process To calculate a result you need to Measure the flow rate of process coolant gallons per minute or GPM Determine the ΔT of the process coolant
Further DetailsOnline Slurry Calculator The Paterson Cooke Slurry Calculator is a simple calculator of slurry properties Use it to determine the concentration of the slurry if you know the density or vice versa It is also a useful tool to determine mass transfer rates Launch Slurry Calculator Disclaimer Help Online Slump Calculator The Paterson
Further DetailsAccurately measure the water temperature entering and exiting your process Use this formula to calculate BTU cooling required Formula BTU Flow Rate In GPM of water x Temperature Leaving Process Temperature Entering Process x 5004 Formula changes with fluids others than straight water BTU Calculator for Weighed Water Test
Further DetailsOversize the chiller by 20 Ideal Size in Tons Tons x 12 You have the ideal size for your needs For example what size chiller is required to cool 40GPM from 70°F to 58°FT°F 70°F 58°F 12°F BTUhr 40gpm x 60 x 833 x 12°F 239904 BTUhr Ton Capacity 239904 BTUhr ÷ 12000 19992 Tons
Further DetailsMay 19 2017 · Inlet water flow rate 10 000 gpm Inlet water temperature 100 o F Outlet water temperature 85 o F Drift loss 002 Cycles of concentration 5 Recall again cooling tower makeup water evaporation loss drift loss blowdown Let’s calculate each component Evaporation loss 000085 x 10 000 x 10085 1275 gpm
Further DetailsDec 29 2018 · If for instance the chiller must move 300 gallons per minute 13 x 300 3900 gallons per minute Multiply your answer by 500 This converts the volumetric flow rate to a mass flow rate which is measured in pounds of water per hour
Further DetailsSlurry Calculator Help Introduction The Paterson Cooke Slurry Toolkit is a simple calculator of slurry properties Use it to determine the concentration of the slurry if you know the density or vice versa It is also a useful tool to determine slurry flow properties The toolkit is meant for use by engineers technicians and
Further DetailsFor a well the yield is considered the maximum rate in gallons per minute GPM that a well can be pumped without lowering the water level in the borehole below the pump intake For most singlefamily homes a minimum flow of 6 GPM is suggested from a well or spring
Further DetailsOversize the chiller by 20 Ideal Size in Tons Tons x 12 You have the ideal size for your needs For example what size chiller is required to cool 40GPM from 70°F to 58°FT°F 70°F 58°F 12°F BTUhr 40gpm x 60 x 833 x 12°F 239904 BTUhr Ton Capacity 239904 BTUhr ÷ 12000 19992 Tons
Further DetailsFlow Rate Calculator Easily calculate the volumetric flow rate of a pipe aka discharge rate given its diameter for a round pipe height width for a rectangular one and the velocity of the liquid or gas flowing through it The flow rate calculator can also calculate the mass flow rate of liquids given the liquid density is known Input and output support metric and imperial
Further DetailsWhat is Volumetric Flow Rate The volumetric flow rate which is also commonly referred to as the rate of liquid flow or volume flow rate is the volume of a given fluid that flows within a unit of is usually denoted by the Q symbol The rate at which a liquid flows will vary according to area of the pipe or channel through which it is passing and the velocity of the liquid
Further DetailsDry saturated steam at 3 bar g is used to heat water flowing at a constant rate of 15 ls from 10°C to 60°C hfg at 3 bar g is 2 1334 kJkg and the specific heat of water is 419 kJkg °C Determine the steam flowrate from Equation 267 As 1 litre of water has a mass of 1 kg the mass flowrate 15 kgs
Further Detailstonhour 24618 kWhour chilled water storage system serving a hospital By optimizing the operation of the building air handling units chilled water pumps chiller plant and the thermal storage system the storage tank is better charged while chiller run time is reduced Both onpeak and offpeak electrical demands are expected to be reduced
Further DetailsA waterchiller refrigeration ton is defined as 1 Refrigeration Ton RT 1 TONS cond 12000 Btuh 200 Btumin 30259 k Caloriesh 12661 kJh 3517 kW 1 kW 02843 Refrigeration Ton RT A ton is the amount of heat removed by an air conditioning system that would melt 1 ton 2000 lbs of ice in 24 hours The heat required to melt
Further Detailsprocess water for cooking wood chips to make pulp as a medium for heat transfer and for washing the pulpwood the woodpulp and the machines that handle the pulp About 3200 million gallons of water was withdrawn from surface and groundwater
Further Detailsprocessing 2100 Lbs per hour of High Density Polyethylene Btuh 2100 LbsHr x 4 machines x 10 Spec Heat x 450°115° Btuh 8400 x 1 x 335 Btuh 2814000 Btuh or 2345 refrigeration tons A central water cooled chiller will reject 1876 tower tons to the water system for the chiller
Further DetailsFlow Rate By Mass Converter Metric Tonne Per Hour thour Online converter page for a specific unit Here you can make instant conversion from this unit to all other compatible units
Further DetailsJul 16 2004 · For a water cooled chiller the total heat of rejection is 125 times the evaporator capacity So when you say 24 or 30 GPM per ton you are reffering always to EVAPORATOR tons 24 GPM 125 30 GPM Most standard evaporators and condensers are sized using 24 GPMTON 30 for condensers 10 F DT 910 F approach etc
Further DetailsNo matter what your application there is a single formula for determining the size of chiller you need Before you begin you must know three variables The incoming water temperature The chilled water temperature required The flow rate For our example we will calculate what size chiller is required to cool 40 GPM gallons per minute from 70 °F to 58 °F
Further DetailsMatec designs manufactures and installs turnkey plants for the purification and filtration of waste water Filter Press To obtain perfectly dried mud cakes Matec America filter press is the best technicaleconomical solution
Further Details